AED
AED (Automated External Defibrillator): Reliable Emergency Rescue Device for Extracorporeal Circulation & Clinical Cardiac Care
For global medical procurement teams and clinical engineering departments, reliable emergency defibrillation backup is essential during extracorporeal circulation surgery and critical patient care. Sudden arrhythmia and cardiac arrest require fast, accurate, and safe defibrillation response. A high-performance AED (Automated External Defibrillator) delivers intelligent ECG analysis, rapid charging, and dual adult/pediatric rescue modes, effectively improving patient survival rates in high-risk clinical and surgical scenarios. This professional B2B guide covers authoritative definitions, technical parameters, application rules and buyer selection standards.
Table of Contents
- 1. What Is an AED (Automated External Defibrillator)?
- 2. AED Operational Mode Classification
- 3. Full Technical Parameters & Official Data Source
- 4. Core Clinical & Extracorporeal Circulation Applications
- 5. Standard AED Selection Steps for Medical Buyers
- 6. Professional FAQs for Procurement & Clinical Use
- 7. Summary & Official B2B Inquiry
1. What Is an AED (Automated External Defibrillator)?
An Automated External Defibrillator (AED) is a portable intelligent medical rescue device designed to treat sudden cardiac arrest and fatal arrhythmia. It automatically analyzes patient ECG rhythms, delivers accurate defibrillation energy, and provides real-time CPR guidance. Widely deployed as emergency backup equipment for extracorporeal circulation surgery rooms, ICUs, and first-aid systems, it ensures rapid response to critical cardiac emergencies during high-risk surgical and postoperative care procedures.
[Image placeholder: Medical AED device product display]
2. AED Operational Mode Classification
This medical-grade AED supports dual working modes to adapt to different clinical team operation habits and emergency scenarios:
- Fully Automatic Mode: Realizes full intelligent ECG analysis, charging and defibrillation without manual trigger, suitable for rapid first aid and non-professional auxiliary rescue scenarios
- Semi-Automatic Mode: Automatically analyzes rhythms and completes charging, requiring manual confirmation for defibrillation, safer for precise operation in operating rooms and extracorporeal circulation surgical environments
3. Full Technical Parameters & Official Data Source
Verified Official AED Technical Specifications
- Working Waveform: Biphasic truncated exponential waveform with auto impedance compensation (20–200Ω)
- Output Energy: Adult mode 150J/200J; Pediatric & Infant mode 50–75J
- Analysis & Charging Speed: ECG rhythm analysis ≤10s; full charge completed within 6–8 seconds
- Operation Guidance: Voice + LED visual guidance, built-in real-time CPR coaching metronome
- Power Supply: Disposable Li-MnO₂ lithium battery; 5–7 years long standby life, supports ≥120 continuous shocks
- Environmental Adaptability: Working & storage temperature 0℃–50℃; humidity 5%–95% non-condensing; IP55 dust & water resistance
- Portability: Dimension 280×210×80mm, net weight ≤2.6kg, equipped with dedicated portable carry case
- Data Management: Built-in memory for 90 mins ECG waveforms and rescue event recording; optional Bluetooth data export
- Consumables: Adult/child disposable defibrillator pads with 2-year shelf life
- Self-Check System: Automatic daily, weekly and monthly self-test with status indicator reminder
- Qualification: CE medical certified, fully compliant with IEC 60601 international medical device standards
Data Source: Power On Medical official AED product technical specification file
4. Core Clinical & Extracorporeal Circulation Applications
As a critical emergency supporting device for extracorporeal circulation and cardiac surgery, the AED guarantees intraoperative and postoperative emergency response capabilities in the following scenarios:
- Emergency defibrillation backup during extracorporeal circulation cardiac surgery
- ICU critical patient real-time cardiac rhythm monitoring and rescue
- Operating room routine emergency equipment deployment
- Hospital ward, ambulance and medical workstation first-aid configuration
- Public medical emergency stations and medical institution standardized equipment matching
- Pediatric and infant low-energy precise defibrillation rescue scenarios
5. Standard AED Selection Steps for Medical Buyers
[Image placeholder: AED clinical emergency application scenario]
- Confirm dual-mode demand: Select fully automatic or semi-automatic model according to surgical room and first-aid team configuration
- Verify dual energy output: Ensure adult and pediatric adjustable energy modes to cover full-age clinical rescue
- Check response efficiency: Confirm ≤10s ECG analysis and 6–8s fast charging performance for time-sensitive emergency scenarios
- Validate battery performance: Confirm 5–7 years standby life and ≥120 shocks capacity for long-term batch deployment
- Check environmental grade: Prioritize IP55 dustproof and waterproof design for complex hospital working environments
- Verify standard certification: Confirm CE and IEC 60601 medical compliance to meet international hospital procurement standards
- Match supporting consumables: Confirm supporting disposable defibrillation pads with qualified shelf life
6. Professional FAQs for Procurement & Clinical Use
Q1: What energy levels does this medical AED support?
A1: It provides 150J/200J for adult mode and 50–75J for pediatric and infant mode, supporting precise defibrillation for different patient groups.
Reference: Official product energy parameter table
Q2: How fast is the AED analysis and charging speed?
A2: The device completes ECG rhythm analysis within 10 seconds and finishes full charging in 6–8 seconds, ensuring rapid emergency rescue response.
Reference: Official technical performance data
Q3: What is the standby battery life and shock capacity?
A3: Equipped with disposable Li-MnO₂ lithium battery, featuring 5–7 years standby life and supporting more than 120 continuous shocks.
Reference: Official power system specification
Q4: What environmental resistance and certification does this AED have?
A4: It adopts IP55 dust and water resistance, works stably at 0℃–50℃, and holds CE medical certification compliant with IEC 60601 medical device standards.
Reference: Official qualification document
Q5: Does the device support data recording and export?
A5: Yes, it built-in memory stores 90 minutes of ECG waveforms and rescue events, with optional Bluetooth data export for clinical record management.
Reference: Official data function description
7. Summary & Official B2B Inquiry
Medical-grade AED is an indispensable emergency rescue device for modern extracorporeal circulation surgery, cardiac clinical treatment and hospital first-aid systems. With biphasic waveform technology, dual adult/pediatric energy modes, fast response speed, long standby battery life and complete international certifications, it meets high-standard clinical and batch procurement demands. As a professional medical device manufacturer with over 20 years of experience, Power On Medical owns ISO 13485 & ISO 9001 certified clean-room production lines, one-stop R&D and manufacturing system, and long-term cooperation with top global medical enterprises, providing stable bulk supply, technical documentation and customized solutions for global B2B medical buyers.
Get official AED datasheets, bulk pricing and professional technical support:
Official Website: www.poweronmedical.com
WhatsApp: +86 13580813246
Email: sales@poweron-mould.com
Manager Tel: 0755-89203200